== Data Access == <> === Run Query === http://atlas-runquery.cern.ch/ === Good Runs Lists === https://twiki.cern.ch/twiki/bin/view/Atlas/GoodRunsLists https://twiki.cern.ch/twiki/bin/view/Atlas/GoodRunsListsTutorial https://twiki.cern.ch/twiki/bin/view/AtlasProtected/GoodRunListsForData === Interesting Runs === https://twiki.cern.ch/twiki/bin/view/AtlasProtected/InterestingRuns2009 === Luminosity Calculation === https://twiki.cern.ch/twiki/bin/view/Atlas/CoolLumiCalc https://twiki.cern.ch/twiki/bin/viewauth/Atlas/CoolLumiCalcTutorial === TAGs === https://twiki.cern.ch/twiki/bin/view/Atlas/CommissioningTag === Trouble shooting === When running over ESDs first, encountered problems with database access, error messages like: {{{ IOVDbSvc ERROR Tag COMCOND-ES1CT-003-00 cannot be resolved for folder /LAR/Align }}} Reason: Database conditions not properly set Solution: In exeSingleTopDPDMaker.py add somewhere at the beginning (e.g. before sequence initialisations): {{{ from AthenaCommon.GlobalFlags import GlobalFlags GlobalFlags.DetGeo.set_atlas() GlobalFlags.DataSource.set_data() from IOVDbSvc.CondDB import conddb }}} Details can be found: * https://twiki.cern.ch/twiki/bin/view/Atlas/CoolTroubles#Tag_not_defined_or_cannot_be_res * https://twiki.cern.ch/twiki/bin/view/Atlas/CoolIOVDbSvcConfigurable#Conditions_DB_in_standalone_cont ---- Second error: POOL file GUID requested by COOL is not found in the attached catalogues. Gives messages like: {{{ T_AthenaPoolCnv ERROR poolToObject: caught error: FID "74981861-8AD2-DE11-95BD-001CC466D3D3" is not existing in the catalog ( POOL : "PersistencySvc::UserDatabase::connectForRead" from "PersistencySvc" ) PixelDetectorManager ERROR Cannot find AlignableTransformContainer for key /Indet/Align - no misalignment PixelDetectorManager FATAL Unable to apply Inner Detector alignments }}} Solution: could be resolved by either running on lxplus, where database is up-to-date or by following instructions here: * https://twiki.cern.ch/twiki/bin/view/Atlas/CoolTroubles#Missing_POOL_file On lxplus do: {{{ grep -A 2 74981861-8AD2-DE11-95BD-001CC466D3D3 /afs/cern.ch/atlas/conditions/poolcond/catalogue/poolcond/PoolCat_oflcond.xml }}} or {{{ grep -A 2 74981861-8AD2-DE11-95BD-001CC466D3D3 /afs/cern.ch/atlas/conditions/poolcond/catalogue/poolcond/PoolCat_comcond.xml }}} In this case, as we are looking at data, only the second gives output. Mind the different names for the xml-files for Monte Carlo and real data. Copying /afs/cern.ch/atlas/conditions/poolcond/catalogue/poolcond/PoolCat_comcond.xml to the share directory of SingleTopDPDMaker fixes the problem. If it still doesn't work then (was the case for me when processing mc09_900), follow the instructions given here and create a local database: https://twiki.cern.ch/twiki/bin/view/Atlas/AthenaDBAccess#Switching_to_use_local_SQLite_fi {{{ ln -s /afs/cern.ch/user/a/atlcond/coolrep/sqlite200 sqlite200 ln -s /afs/cern.ch/atlas/project/database/DBREL/packaging/DBRelease/current/geomDB geomDB }}} === Detector Description and Condition === You have to make sure you set the right detector conditions. There have been defined several new conditions, details: * https://twiki.cern.ch/twiki/bin/view/Atlas/AtlasGeomDBTags * https://twiki.cern.ch/twiki/bin/view/Atlas/AtlasDBRelease821TopTags